Necessary Checks to Ensure Safety in Any Field Where Electrical Systems Exist
Certain checks are necessary to ensure safety in any field where electrical systems are present. In particular, grounding measurement is extremely important for the health and safety of the electrical system. Grounding measurement can be performed for extensive electrical systems in industrial facilities, office buildings, and many other enterprises. Grounding measurement, which provides important clues about the health of the electrical system, is a procedure that every facility must carry out. In this regard, it is extremely important that grounding measurements are performed regularly and consistently.
In addition to grounding safety, it also helps ensure the proper functioning of protective elements in electrical systems. Especially for electrical protection systems such as residual current relays, lightning arresters, magnetic thermal circuit breakers, and automatic fuses, grounding measurement is required to achieve the desired values.
Grounding Process
Grounding measurement, which is vital for many fields, involves certain stages. Generally, multiple grounding measurements are performed. Below, you can find details related to grounding measurement.
Rod Electrode Grounding: In the grounding process, the support of at least 2-3 conductive rods is required. The diameter of the rods used in rod electrode procedures may vary depending on the electrical current hazard in the area where grounding is performed. Generally, it is sufficient to choose these rods between 12.5 mm and 40 mm. Instead of using a single long rod, multiple rod pieces can be used to prevent problems that may arise during grounding measurement.
Goose Foot Grounding: For this type of grounding measurement, digging is required in three branches. Thus, the soil must be dug into fan-shaped channels with a depth of 80 cm. Since the shape of the channels resembles a goose foot, this name has been attributed.
Plate Electrode Grounding: In plate grounding measurements, instead of the conductive rods used in other methods, plates are preferred. The plates used for measurement must be made of copper with a thickness of at least 1.5 mm or galvanized sheet of 3 mm. Additionally, the surface area of the plates must be at least 0.5 m^2. It is important to ensure that the soil in contact with the plate surface is sifted.
Band Electrode Grounding: In this method, the copper band is preferred as the conductive element. If the band is round, its diameter must be at least 8 mm, and if it is flat (blade-like), the size must be 25×2 mm. Furthermore, it is very important that the soil around the band is sifted.